Three layer polyethylene anticorrosion is one of the main technical system of buried pipeline corrosion protection at home and abroad. It has good corrosion resistance, low water absorption and high mechanical strength. It has been used more and more widely in the field of buried water conveyance, gas transmission and pipeline transportation in recent years.
Product Details:

3PE Coating Anti-Corrosion Insulation Steel Tube

Product Name

ERW steel pipe

Material

A53 GR.B, A36, ST52, ST35, ST42, ST45,X42, X46, X52, X56, X60, X65, X70

Size

 1/2"—48" (DN15mm-1200mm)

Standard

API5L , ASTM A106 Gr.B, ASTM A53 Gr.B, ASTM A179/A192,ASTM A513-2007,ASTM   A671-2006,ASTM A672-2006 ,BS EN10217, BS EN10296,BS EN 39 ,BS 6323 ,DIN EN   10217-1-2005

Certificates

API5L, ISO 9001:2008, SGS, BV, CCIC.

Wall thickness

SCH10, SCH20, SCH30, STD, SCH40, SCH60, SCH80, SCH100 SCH120, SCH160, XS, XXS

Surface   Treatment

black paint, varnish, oil, galvanized, anti-corrosion coated.

Pipe Ends

Under 2 inch plain end. 2 inch and above Beveled. Plastic caps (small OD). Iron   protector (large OD).

Marking

Standard marking, or according to your request. Marking Method: Spray white paint

Pipe Length

1. Single Random Length and double Random Length.

2. SRL:3M-5.8M  DRL:10-11.8M or As clients requested length

3. fixed   length(5.8m, 6m, 12m)

Packaging

Loose package; Packaged in bundles(2Ton Max);  bundled pipes with two slings at the both end for easy loading and discharging; wooden cases; waterproof woven bag.

Test

Chemical Component Analysis, Mechanical Properties, Technical Properties, Exterior   Size Inspection,hydraulic testing , X-ray Test.

Application

liquid delivery,Structure pipe,construction, petroleum cracking,oil pipe,gas pipe

Advantages

1.Reasonable price with excellent quality

2.Abundant stock and prompt delivery

3.Rich supply and export experience, sincere service

4.Reliable forwarder, 2-hour away from port.


Three layer polyethylene anticorrosion is one of the main technical system of buried pipeline corrosion protection at home and abroad. It has good corrosion resistance, low water absorption and high mechanical strength. It has been used more and more widely in the field of buried water conveyance, gas transmission and pipeline transportation in recent years.

Product specifications: diameter of 48-- with 3000

Material: Q235B, Q345B, 10# steel, 20# steel, X42-X80 grade and so on.

Implementation standard: GB/T23257-2009 technical standard for polyethylene anticorrosion coating for buried steel pipeline

SY/T0413-2002 technical standard for polyethylene corrosion resisting layer of buried steel pipeline

DIN30670-91 technical standards for polyethylene coatings for steel tubes and fittings in Germany

CAN/CSA-Z245.21-M92 Canadian technical standard for polyethylene pipe anticorrosive coating on outer wall


Purpose:

The outer coating is mainly used for oil transportation by pipelinecorrosion protection of buried before; mainly from the inner coating reducesdrag reduction pipeline investment and operation and maintenance costs.


Pipe external corrosion

1, single FBE corrosion (FBE) Single-layerFBE Coating Epoxy powder layer because of its excellent corrosion resistance,insulation resistance and long service life and become an advanced anti-corrosioncoating of the outer pipe. Sub-ordinary nature (thickness: 300 ~ 400um) andenhanced (thickness: 400 ~ 500um) two kinds.

2, double FBE corrosion (2FBE)

Double epoxy powder coated outer coating is a composite structure,consisting of anti-corrosion epoxy powder primer and epoxy powder resistant tomechanical damage the surface layer of a coating film is completed. Normal sex(thickness ≥ 620um); enhanced (thickness ≥ 800um)

3, two polyethylene / polypropylene anticorrosion (2PE/2PP)

Two polyethylene / polypropylene layer with good corrosion resistance,insulation resistance, long service life and resistance to mechanical damage.Sub-normal and enhanced thickness according to pipe size varies: Common Min1.8mm; enhanced minimum 2.5mm.

4, three layer polyethylene / polypropylene anticorrosion (3PE/3PP)

Three layer polyethylene / polypropylene layer with excellent corrosionresistance, insulation resistance, longer service life and a certain degree ofresistance to mechanical damage of the coating has been widely used in variouslarge-scale projects of the corrosion in the pipeline. Common type andstrengthened type two, thickness of the pipe size varies: Common minimumthickness 1.8mm; enhanced minimum thickness of 2.5mm.

Anti-corrosion steel pipe

DN100-1500 can be carried out within a steel pipeanti-corrosion, rust red iron centrifugal spray or two-component liquid epoxypaint or other coatings specified by the user, the treated for corrosionprotection of steel pipe wall processing


3PE/PP Coating performance:

Project

Peel strength(N/cm)

Cathodic strip(mm)(65℃,48h)

Impact    strength (J/mm)

Bending resistance (2.5°)

20±5℃

50±5℃

Performance

≥60

≥40

≤10

≥5

No cracking of polyethylene

Uses: products are widely used in oil pipelines, natural gas pipelines, heating pipes, water pipelines.


3PE coating pipes


image001


3PE coating Pipe has three layer PE antisepsis structure: the first layer with epoxy powder (FBE> 100um), the second layer with adhesive (AD), 170 - 250um, the third layer with polyethylene (PE) 2.5 ~ 3.7mm.


image002


image003


Integration of them and solid steel pipe make form a good coating.

Diameter range 60mm-1420mm, wall thickness 2.5-18mm, which is a good anti-corrosion method, generally can improve the service life of 50 years, not only extended the replacement cycle of the underground plumbing, and significant cost savings for the provides a strong role in nation-building. 

3PE anti-corrosion is the most commonly used method of anti-corrosion, in addition to 2PE, 2PP, 3PP, their manufacturing process is similar to but different raw materials, this anti-corrosion characteristics of the simple fabrication process, the preservative effect, inexpensive pipe manufacturing industry generally agree that corrosion.


image004


ADVANTAGES OF THE THREE-LAYER COATING SYSTEM

·         Excellent corrosion resistance.

·         When exposed to either acid or alkaline media, an extended lifetime in highly corrosive soils is assured.

·         Strong steel adhesion: 20 times more adhesive than traditional plastic tape systems.

·         Excellent cathodic disbondment test results.

·         Excellent mechanical resistance.

High dielectric resistance : Superior bending ability for pipe laying applications

High impermeability: Both the high-density polyethylene and polypropylene have low water permeation characteristics that allow improved isolation from the surrounding sea water compared to other coating systems


3PE anticorrosive steel pipe characteristics:

·         very high tightness,which can greatly save energy, reduce costs, protect the environment in long-term operation.

·         strong corrosion resistance, the construction side simply speed, the service life can be up to 30-50 years.

·         with good resistance to corrosion and impact resistance, low water absorption, the PE (less than 0.01%) at low temperatures.

·         high strength epoxy, PE absorbent and hot melt adhesive softness, etc., have high corrosion reliability.


Hot Tags: 3pe coating anti-corrosion insulation steel tube, China, suppliers, manufacturers, factory
Related Products
Feedback: